600VDC catenary converter

Under-rack installation

The 600 Vdc 16kVA/25kW static converter is specifically designed for railway vehicles that operate on 600 Vdc HV supplied from the overhead line.

It can operate with a voltage range of 450 Vdc to 780 Vdc. It supplies a single-phase voltage of 120V@60Hz for the train's auxiliary loads, with a total power of 16kVA, and the DC loads plus the battery charge at 37.5 Vdc with a total power of 25kW.

It also contains an internal 600V power supply module to start the APS in case of a discharged battery (dead battery start function).

The APS is installed under the rack and is naturally ventilated by heat sinks. The magnetic components are housed in an IP20 enclosure, while the remaining electronic circuitry and other power components are installed in an IP65 clean compartment.

Features

Features 1CT MS-160F-25D (750 VDC) 1CT MS-16F-25D (600VDC) 2CT MS-170F-20D (1500VDC)
Strain 450 – 1000 Vdc 450 – 780 Vdc 1000-1800 Vdc
Overall dimensions 2020x1200x700 2290x605x445 2200x856x655
Maximum overvoltage 4kV o.5msec IEC 61287-1 IEC 61287
Weight (Kg) 927 488 695
AC output voltage 400 Vac@50Hz 120 Vac@60Hz 1 phase 400 Vac@50Hz
Operating temperature (°C) ‐25/85 -30/50 ‐15/85
AC Output Phases 3 + N 3 + N
Level of Protection IP66 (IEC 60529) IP66 (IEC 60529) ‐25/85
AC rated power 160kVA (140kW) 16kVA (12,8kW) 170kVA (140kW)
Noise emission <70 Db at 1m <61 Db at 3m <75 Db at 1m
DC Output Voltage Regulation 110V 37,5V 110V
Power connections Cables Cables Cables
DC Output Power Regulation 25kW 25kW 20kW
Control connections Conector Harting Conector Harting Conector Harting
Contributions to the center 400 Vac 3 phases 400 Vac 3 phases
Shock and Vibration IEC 61373 EN 12663-1 IEC 61373 EN 12663-1 IEC 61373 EN 12663-1
Unregulated DC output voltage 110V
train network Ethernet Ethernet
Unregulated DC output power 5kW
Location Under the frame Under the frame Under the frame
Overall efficiency >80% of 10% to 100% of the load >80% of 10% to 100% of the load >92% of 50% of the load
Refrigeration Forced Refrigeration Forced
AC Transient Power 30kVA, PF<0,5, 5s
Fire resistance NFPA 130
Line gaps >10ms at full load and nominal voltage
Control input power supply 110 Vdc
Maximum current limit 667A