The 2CT MS-170F-20D auxiliary converters are specifically designed for railway vehicles operating under 1500Vdc catenaries.

The APS supplies galvanically isolated 400V@50Hz three-phase AC + neutral to the train's auxiliary loads, providing a total power of 165kVA, and to the DC loads (essential and non-essential) plus the battery charging at 110Vdc, providing a total power of 20kW. The equipment efficiency is 92% from 50% to 100% load.

The APS is installed under the rack and is naturally ventilated by heat sinks. The magnetic components are housed in an IP20 enclosure, while the remaining electronic circuitry and other power components are installed in an IP65 clean compartment.

The converter is equipped with an external 400Vac@50Hz AC workshop power supply. This module allows the battery charger and other AC loads to be powered without using the high-voltage power supply. The converter also integrates a pre-charge circuit and an input filter.

Features

Features 1CT MS-160F-25D (750 VDC) 1CT MS-16F-25D (600VDC) 2CT MS-170F-20D (1500VDC)
Strain 450 – 1000 Vdc 450 – 780 Vdc 1000-1800 Vdc
Overall dimensions 2020x1200x700 2290x605x445 2200x856x655
Maximum overvoltage 4kV o.5msec IEC 61287-1 IEC 61287
Weight (Kg) 927 488 695
AC output voltage 400 Vac@50Hz 120 Vac@60Hz 1 phase 400 Vac@50Hz
Operating temperature (°C) ‐25/85 -30/50 ‐15/85
AC Output Phases 3 + N 3 + N
Level of Protection IP66 (IEC 60529) IP66 (IEC 60529) ‐25/85
AC rated power 160kVA (140kW) 16kVA (12,8kW) 170kVA (140kW)
Noise emission <70 Db at 1m <61 Db at 3m <75 Db at 1m
DC Output Voltage Regulation 110V 37,5V 110V
Power connections Cables Cables Cables
DC Output Power Regulation 25kW 25kW 20kW
Control connections Conector Harting Conector Harting Conector Harting
Contributions to the center 400 Vac 3 phases 400 Vac 3 phases
Shock and Vibration IEC 61373 EN 12663-1 IEC 61373 EN 12663-1 IEC 61373 EN 12663-1
Unregulated DC output voltage 110V
train network Ethernet Ethernet
Unregulated DC output power 5kW
Location Under the frame Under the frame Under the frame
Overall efficiency >80% of 10% to 100% of the load >80% of 10% to 100% of the load >92% of 50% of the load
Refrigeration Forced Refrigeration Forced
AC Transient Power 30kVA, PF<0,5, 5s
Fire resistance NFPA 130
Line gaps >10ms at full load and nominal voltage
Control input power supply 110 Vdc
Maximum current limit 667A