imagen de Convertidor para catenaria de 750VDC

750VDC catenary converter

Under-rack installation

The 1CT MS-160F-25D auxiliary converters are specifically designed for railway vehicles that operate on 750Vdc supplied from the catenary.

The APS supplies galvanically isolated 400Vac@50Hz (3 phases + neutral) to the train's auxiliary loads, providing a total power of 160kVA. It also supplies 110Vdc for the train's essential loads, non-essential loads, and battery charging, providing a total power of 25kW. The equipment's efficiency is 92% between 50% and 100% load.

The APS is installed under the rack and features forced ventilation via a special fan. All magnetic components are located in an IP20 enclosure, while the remaining electronic circuitry and other power components are installed in an IP65 clean compartment, both cooled by the fan.

At the same time, it is equipped with an external workshop power supply of 400 Vac@50Hz, which is converted to 110 Vdc for the train's emergency circuits. The converter also integrates a pre-charge circuit and an input filter as part of its power electronics.

Features

Features 1CT MS-160F-25D (750 VDC) 1CT MS-16F-25D (600VDC) 2CT MS-170F-20D (1500VDC)
Strain 450 – 1000 Vdc 450 – 780 Vdc 1000-1800 Vdc
Overall dimensions 2020x1200x700 2290x605x445 2200x856x655
Maximum overvoltage 4kV o.5msec IEC 61287-1 IEC 61287
Weight (Kg) 927 488 695
AC output voltage 400 Vac@50Hz 120 Vac@60Hz 1 phase 400 Vac@50Hz
Operating temperature (°C) ‐25/85 -30/50 ‐15/85
AC Output Phases 3 + N 3 + N
Level of Protection IP66 (IEC 60529) IP66 (IEC 60529) ‐25/85
AC rated power 160kVA (140kW) 16kVA (12,8kW) 170kVA (140kW)
Noise emission <70 Db at 1m <61 Db at 3m <75 Db at 1m
DC Output Voltage Regulation 110V 37,5V 110V
Power connections Cables Cables Cables
DC Output Power Regulation 25kW 25kW 20kW
Control connections Conector Harting Conector Harting Conector Harting
Contributions to the center 400 Vac 3 phases 400 Vac 3 phases
Shock and Vibration IEC 61373 EN 12663-1 IEC 61373 EN 12663-1 IEC 61373 EN 12663-1
Unregulated DC output voltage 110V
train network Ethernet Ethernet
Unregulated DC output power 5kW
Location Under the frame Under the frame Under the frame
Overall efficiency >80% of 10% to 100% of the load >80% of 10% to 100% of the load >92% of 50% of the load
Refrigeration Forced Refrigeration Forced
AC Transient Power 30kVA, PF<0,5, 5s
Fire resistance NFPA 130
Line gaps >10ms at full load and nominal voltage
Control input power supply 110 Vdc
Maximum current limit 667A